Thermostat Operation (Raise Temp 5 deg, check & clear faults)- VISUALLY INSPECT: Filter-clean Condensate Drain (pump, lines & trap)-n/a Wiring and Connections-secure w/ no breaks or frays Vent Pipes-secure and venting properly Heat Exchangers-good Burners-clean and operational Blower Cleanliness-clean MEASURE: Low Voltage-26.5 Line Voltage-123.5 Flame Sensor-4.6uA( pulled and cleaned) Inducer Motor Amps-.76a Inducer Capacitor-n/a Blower Amps-4.81 Blower Capacitor-7.4uF rated 7.5uF Ignitor Ohms-53.9 Fuel Type-natural Gas Pressure Outlet-3.81(adjusted to 3.5inH2O) Gas Pressure Inlet (if out of range)- Temp Rise-51.2deg Humidifier & Pad- COMBUSTION ANALYSIS:could not perform due to type of flu vent Return Stat to Customer Settings

Near Beavercreek, OH 45324
Beavercreek, OH - Thermostat Operation (Raise Temp 5 deg, check & clear faults)-
VISUALLY INSPECT:
Filter-clean
Condensate Drain (pump, lines & trap)-n/a
Wiring and Connections-secure w/ no breaks or frays
Vent Pipes-secure and venting properly
Heat Exchangers-good
Burners-clean and operational
Blower Cleanliness-clean
MEASURE:
Low Voltage-26.5
Line Voltage-123.5
Flame Sensor-4.6uA( pulled and cleaned)
Inducer Motor Amps-.76a
Inducer Capacitor-n/a
Blower Amps-4.81
Blower Capacitor-7.4uF rated 7.5uF
Ignitor Ohms-53.9
Fuel Type-natural
Gas Pressure Outlet-3.81(adjusted to 3.5inH2O)
Gas Pressure Inlet (if out of range)-
Temp Rise-51.2deg 
Humidifier & Pad-
COMBUSTION ANALYSIS:could not perform due to type of flu vent
Return Stat to Customer Settings
Cody D.

Cody D.

I Replaced the rubber exhaust boot on the 2014 Lennox.

Near Beavercreek, OH 45324
Beavercreek, OH - I Replaced the  rubber exhaust boot on the 2014 Lennox.
Tiffanie W.

Tiffanie W.

here for pressure switch errors on furnace. On arrival the 2013 Tempstar furnace tried to kick on and I can hear water in the inducer. I removed the inducer and dumped the water out. Checked the hoses and condensate trap, everything is clear, after reattaching inducer assembly I got furnace running and my draft on the pressure switch is now much better than it was before with the water in the inducer, after a few minutes of running the inducer now has water in it again, And started flashing pressure switch code, removed rubber boot that connects vent piping to inducer assembly, nothing is blocked in here unsure why water keeps getting into the inducer. Going to try replacing inducer assembly, collecter box, and condensate trap. We had one recently doing the same thing and this corrected the issue.

Near Greene Blvd, Beavercreek, OH 45440
Beavercreek, OH - here for  pressure switch errors on furnace. On arrival the 2013 Tempstar  furnace tried to kick on and I can hear water in the inducer. I removed the inducer and dumped the water out. Checked the hoses and condensate trap, everything is clear, after reattaching inducer assembly I got furnace running and my draft on the pressure switch is now much better than it was before with the water in the inducer, after a few minutes of running the inducer now has water in it again, And started flashing pressure switch code, removed rubber boot that connects vent piping to inducer assembly, nothing is blocked in here unsure why water keeps getting into the inducer. Going to try replacing inducer assembly, collecter box, and condensate trap. We had one recently doing the same thing and this corrected the issue.
Cody D.

Cody D.

I am Performing our Five Star Tune-Up & Safety Check on a 2019 Carrier Gas Furnace. All readings were within manufacturer's specifications, unit operating properly at this time.

Near Beavercreek, OH 45430
Cody D.

Cody D.

Upon tune up inspection for 2019 Carrier furnace, everything is functioning properly and within spec.

Near Beavercreek, OH 45430
Beavercreek, OH - Upon tune up inspection for 2019 Carrier furnace, everything is functioning properly and within spec.
Cody D.

Cody D.

Performing our Five Star Tune-Up & Safety Check on a 2019 Carrier . All readings were within manufacturer's specifications, unit operating properly at this time.

Near Beavercreek, OH 45324
Beavercreek, OH - Performing our Five Star Tune-Up & Safety Check on a 2019 Carrier  . All readings were within manufacturer's specifications, unit operating properly at this time.
Hassan H.

Hassan H.

Performing our Five Star Tune-Up & Safety Check on a 2019 Carrier . All readings were within manufacturer's specifications, unit operating properly at this time.

Near Beavercreek, OH 45430
Beavercreek, OH - Performing our Five Star Tune-Up & Safety Check on a 2019 Carrier  . All readings were within manufacturer's specifications, unit operating properly at this time.
Cody D.

Cody D.

I preformed a Real Estate HVAC Inspection. Upon arrival I went through furnace tune up list and confirmed that system is working within manufacture specifications Went through ac tune up list and confirmed that system is working within manufacture specifications Both systems functioning properly upon departure

Near Beavercreek, OH 45324
Hassan H.

Hassan H.

Performing our Five Star Tune-Up & Safety Check on a 2009 Amana . All readings were within manufacturer's specifications, unit operating properly at this time.

Near Beavercreek, OH 45324
Beavercreek, OH - Performing our Five Star Tune-Up & Safety Check on a  2009 Amana  . All readings were within manufacturer's specifications, unit operating properly at this time.
Josh A.

Josh A.

Customer advised AC was having trouble keeping temp, the previous company that was out replaced something but he was not sure What they repaired Turned unit on at stat, indoor and outdoor unit came on filter was clean as was outdoor unit. Checked pressures found system to be over charged. Removed refrigerant and brought pressure to within manufactures specs. Checked delta t and found it to be 21.1

Near Beavercreek, OH
Beavercreek, OH - Customer advised AC was having trouble keeping temp, the previous company that was out replaced something but he was not sure What they repaired Turned unit on at stat, indoor and outdoor unit came on filter was clean as was outdoor unit. Checked pressures found system to be over charged. Removed refrigerant and brought pressure to within manufactures specs. Checked delta t and found it to be 21.1